Electrical safety
A current of about 10 to 20 mA through the body can lock the hand onto a wire, and a person soaked with water may have only 10 kΩ of resistance.
Two kinds of danger: heat and shock
Electricity can hurt in two ways. A thermal hazard is too much power turning into heat where it should not, for example inside a wall, where it can start a fire. A shock hazard is current passing through a person. Both come straight out of the formulas in this course, P = V² ÷ R and I = V ÷ R, so you already know enough to see where the danger lies.
Short circuits
A short circuit is a path of very low resistance between the two sides of a supply. It happens, for example, when worn insulation lets the two wires in an appliance cord touch. Because the resistance r of the short is tiny, the power P = V² ÷ r is enormous. OpenStax takes 120 V across a short of 0.100 Ω: 120² ÷ 0.100 = 144,000 W, or 144 kW, far more than any household appliance uses. Heat arrives so fast that insulation melts or catches fire. In the lab the battery is ideal, so a short makes the current run away without limit and the lab flags it in red. A real battery has some internal resistance that limits the current, but it still gets hot quickly.
Overloads, fuses and circuit breakers
A quieter danger is overload: too much current in a wire for too long. The heat in the wire itself is P = I² R_w. A damaged cord with some strands broken might have 2.00 Ω instead of 0.100 Ω; with 10.0 A through it, it turns 200 W into heat inside the cord. Remember from the parallel unit that every appliance switched on adds its current to the supply wires, so plugging many high-power appliances into one outlet strip can overload it even if each one is fine on its own.
Fuses and circuit breakers guard against both problems. They sit in series with the circuit, so all of its current passes through them. A fuse has a metal strip with a low melting point; too much current melts it and breaks the circuit for good, so it must be replaced. A circuit breaker is an automatic switch that opens when the current stays above its limit, and it can be reset. Some devices draw a large current for a moment when they start, like the cold headlight in the Ohm's law unit, so fuses and breakers are built to allow brief surges and trip on sustained overloads.
Drag to turn. Scroll or pinch to zoom.
Drag to turn. Scroll or pinch to zoom.
What current does to the body
How badly a shock hurts depends mainly on the current, and also on the path it takes through the body, how long it lasts and the frequency of the supply. OpenStax gives typical effects for a 1 second shock through the trunk of the body from 60 Hz mains, listed in the table. Values for women are about 60 to 80 percent of those listed. The thresholds are low. The current that makes the hand clamp shut, so the person cannot let go, starts at about 10 to 20 mA, and the heart can go into fibrillation, a fatal irregular beat, from about 100 to 300 mA.
| Current (mA) | Typical effect |
|---|---|
| 1 | Threshold of feeling |
| 5 | Largest harmless current |
| 10 to 20 | Muscles lock; cannot let go; breathing may stop during the shock |
| 50 | Onset of pain |
| 100 to 300 and more | Ventricular fibrillation possible, often fatal |
| 300 | Burns begin, depending on how concentrated the current is |
| 6,000 (6 A) | Heart and breathing may stop during the shock |
Ohm's law shows why water matters so much. Most of the body's resistance is in dry skin. OpenStax gives about 200 kΩ for a person with dry skin, so 120 V drives 120 ÷ 200,000 = 0.6 mA, which passes unfelt. Soaking wet, the same person may have only 10.0 kΩ, and the same 120 V now drives 12 mA, past the point where the hand cannot let go. At the 220 to 230 V used in Korea, Europe and many other places, the same two resistances give about 1.1 mA and 22 mA. Wet hands, bathrooms and anything electrical near water are dangerous for exactly this reason.
Earth wires, double insulation and leakage breakers
Modern wiring adds layers of protection. In the three-wire system, a third earth (ground) wire connects the metal case of an appliance to the ground, holding it near zero volts. If worn insulation lets the live wire touch the case, current flows down the earth wire instead of through the person holding it, and usually trips the breaker. Double-insulated appliances use a protective insulating system instead of an earth connection. They are identified by their marking; the number of plug pins alone is insufficient. A ground fault interrupter, called a residual current device or leakage breaker in many countries, compares the current going out on one wire with the current returning on the other. If they differ by more than a set amount, some current must be leaking somewhere, perhaps through a person, and it cuts the power in a fraction of a second. The set amount depends on the country. North American ground fault interrupters trip at about 5 mA, the largest harmless current in the table. The residual current devices used to protect people in Korea and Europe are usually rated at 30 mA, and Korean wiring rules ask for 15 mA on bathroom sockets.
- Keep electrical devices and sockets away from water, and dry your hands first.
- Do not run many high-power appliances from one outlet strip at once.
- Stop using cords with damaged insulation or plugs that get hot.
- If a fuse blows or a breaker trips again and again, something is wrong: find the cause instead of fitting a bigger fuse.
- Leave mains wiring and repairs inside appliances to a qualified electrician.
- Thermal hazard: power turning to heat where it should not; shock hazard: current through a person.
- A short has tiny r, so P = V² ÷ r is huge.
- Fuses and breakers sit in series and open on sustained overcurrent.
- Effects depend mostly on current: about 10 to 20 mA locks the hand, 100 to 300 mA can stop the heart.
- Wet skin lowers resistance, so the same voltage drives far more current.
- Earth wires, double insulation and leakage breakers (about 5 mA in North America, usually 30 mA in Korea and Europe) add protection.
- 120 V across a short of 0.100 Ω. Power in kilowatts?
- A damaged cord of 2.00 Ω carries 10.0 A. Heat produced in the cord, in watts?
- Dry skin, 200 kΩ, touches 120 V. Current in milliamperes? (one decimal)
- The same person soaking wet, 10.0 kΩ, at 220 V. Current in milliamperes?
- Which current is listed as the largest harmless current?
- 5 mA
- 50 mA
- 300 mA
- 1 A
- How is a fuse connected?
- In series with the circuit it protects
- In parallel with the load
- Only to the earth wire
- In the lab, three 12 Ω bulbs in parallel on 6 V share one fuse. Current through the fuse in amperes?
- A breaker keeps tripping. The sensible response is:
- Find the cause, such as an overload or a faulty appliance
- Fit a bigger fuse or breaker
- Tape the breaker on
- What does an earth (ground) wire do?
- Keeps a metal case near 0 V and carries fault current away
- Supplies extra voltage
- Makes the appliance use less power
- A leakage breaker cuts the power when:
- Outgoing and returning currents differ by more than its set value
- The voltage rises above 230 V
- An appliance is switched off
- Why is a short circuit dangerous even at the battery voltage you use every day?
- The resistance is tiny, so current and heat become huge
- The voltage jumps to thousands of volts
- The charge is used up
Sources for this course (14)
- OpenStax College Physics 2e (openstax.org/books/college-physics-2e): 18.1 Static electricity and charge (amber and the Greek word elektron, like charges repel, glass and silk, Franklin)
- 20.1 Current (I = ΔQ/Δt, 1 A = 1 C/s, truck battery 720 C in 4.00 s, calculator 0.300 mA, conventional current traced to Franklin, drift speed of order 10⁻⁴ m/s, 12-gauge copper wire 2.053 mm, copper density 8.80 × 10³ kg/m³)
- 20.2 Ohm's law (Ohm first showed I ∝ V by experiment, ohmic materials, headlight 12.0 V and 2.50 A = 4.80 Ω, dry person hand to foot about 10⁵ Ω)
- 20.3 Resistance and resistivity (Table 20.1: silver 1.59, copper 1.72, gold 2.44, aluminium 2.65, tungsten 5.6, iron 9.71, nichrome 100, all × 10⁻⁸ Ω·m; headlight cold 0.350 Ω)
- 20.4 Electric power and energy (P = IV = V²/R = I²R, kWh, 1 kWh = 3.6 × 10⁶ J, 60 W bulb for 1000 h at 12 cents per kWh = $7.20, 15 W CFL)
- 20.6 Electric hazards and the human body (thermal and shock hazards, short circuit 120 V across 0.100 Ω = 144 kW, worn cord 2.00 Ω at 10.0 A = 200 W, fuses and circuit breakers, Table 20.3 shock effects, dry skin 200 kΩ, wet 10.0 kΩ)
- 21.1 Resistors in series and parallel
- 21.2 Electromotive force and internal resistance
- 21.3 Kirchhoff's rules
- 23.8 Electrical safety (three-wire system, earth/ground wire, double insulation, GFI trips above 5 mA)
- NIST CODATA elementary charge 1.602176634 × 10⁻¹⁹ C exact (physics.nist.gov/cgi-bin/cuu/Value?e)
- Safety text is general information, not advice for working on mains wiring. Linda Hall Library, Scientist of the Day: Georg Ohm (lindahall.org/about/news/scientist-of-the-day/georg-ohm, experiments 1825 and 1826 with a compass needle, Die galvanische Kette 1827)
- Smithsonian Libraries, Die galvanische Kette (library.si.edu/digital-library/book/diegalvanischeke00ohmg, first publication of Ohm's law, ridiculed at first)
- IEC 60038:2009 standard voltages (230 V grew out of 220 V and 240 V systems; 220 V still used).
Checked: 2026-10-17